Reverse Osmosis Systems

Reverse Osmosis Systems

Higher Efficiency Production – less Reject Water
(especially when using a Water Softener)

Most RO Systems, including p/c, will produce approximately 1ga of Reject Water for every 1ga. of Product (Spot-Free) Water. Diamond Recovery Rates are much higher, resulting in much less Reject Water Production.

  • Adjustable (Automatic) Membrane Flush Sequences.
  • More Safety/Alarm (Adjustable) Features.
  • RO Control also has a ‘Write-Protect’ function that prevents any unwanted personnel from changing RO Control Settings.

Advanced RO Controller (Digital Temp. & TDS Display)

Controller (comes pre-programmed), but allows for more control and feedback, including:

  • Adjustable (Automatic) Membrane Flush Sequences.
    *Note: Diamond RO System comes pre-set so a membrane flush will occur before every RO Production and after every RO Production. Benefit is that on rainy days, your not doing a ‘useless’ membrane flush every 2 hours.
  • More Safety/Alarm (Adjustable) Features.
    Ie. Low Incoming Water Pressure. Way RO is set up from Diamond, if water coming into RO System is less than 15psi for 10+seconds, RO System will shut down. RO System will automatically attempt to re-start 3 times (if all alarm parameters are within guidelines). If RO System shuts down, the RO Control display will indicate “Pressure Fault”, providing feedback for operator. Note: the 10 second time is adjustable.
  • RO Control also has a ‘Write-Protect’ function that prevents any unwanted personnel from changing RO Control Settings.

Ease of Operation

Whether a free standing or wall mount RO System, all Diamond RO units come with a panel/face plate with all ‘adjustable’ components easily accessible and labeled.





Resources
Support
Tech Tips
case proflie



  • Carwash Boilers Inc.
  • |
  • 620 East Smith Rd Medina, OH 44256
  • |
  • 888.316.8514
  • |